Check valves completely prevent the return flow of water so that the consumer can also be operated far above the pump without accidentally filling the hose with air.
The check valve prevents water from escaping from the consumer at a maximum pressure of 10 bar on the pump side.
RV 1
Operating pressure: max. 1800 bar
Opening pressure: 11 bar
Closing pressure: 10 bar